Leave Your Message
A-type Residual Current Relay ASJ20-LD1A
Residual Current Relay

A-type Residual Current Relay ASJ20-LD1A

Power Supply: AC/DC 85~265V

Power Consumption: ≤5W

Elevation: ≤2000m

Class of Pollution: Grade three

Installation Category: Type Ⅲ

    description1

    description2

    General

    ASJ series residual current operated relay can be combined with low voltage circuit breaker or low voltage contactor to form a residual current protection device, which is mainly used for the TT and TN system distribution lines with AC 50Hz and rated voltage of 400V and below. It is used to protect the electrical circuit form ground faults, prevent equipment damage caused by earth fault current and electrical fire accidents, and can also be used to provide indirect contact protection against personal electric shock hazard.

    Products meet the requirements of GB/T 22387-2016 residual current operated relay.

    LCD Display

    LCD displaycwn

    Feature

    A-type Residual Current Relay ASJ20-LD1A (2)hik

    Frequency

    50Hz±5Hz

    Auxiliary power supply

    AC110V, AC220V, DC85 ~270V

    (permissible error ±10%)

    Installation

    DIN Rail 35mm

    Dimension(L*W*H)

    85*54*64mm

    ● A-type residual current measurement

    ● Current percentage light column display

    ● Rated residual operating current can be measured

    ● Limit non-driving time can be set

    ● Two sets of relay output (settable)

    ● With local and remote “test” and “reset” functions

    A-type Residual Current Relay ASJ20-LD1A (3)uwn

    Parameter

    Technical Parameter

    Indicator

    A type

    Power supply

    Voltage range

    AC/DC85~265V

    Power dissipation

    ≤5W

    Input

    Rated residual

    operating current I△n

    0.03, 0.05, 0.1, 0.3, 0.5, 1, 3, 5, 10 , 30(A)note 3

    Limit non-driving time  △t

    0, 0.06, 0.1, 0.2, 0.3, 0.5, 0.8,  1 ,4 , 10(s)note 4

    Rated residual non-operating current I△no

     

    50%I△n

    Performance  characteristics

    Sinusoidal AC and pulsating DC

    Frequency

    50Hz±5Hz

    Operating range

    -20% ~ -10%I△n

    Output

    Output mode

    One is normally closed or open,  and another is for transformation

    Contact capacity

    AL1:8A 250VAC; 5A 30VDC

    AL2:6A 250VAC; 5A 30VDC

    Reset mode

    Local reset, remote reset or automatic reset

    Installation and use environment

    Humidity

    ≤95%RH ,no condensation, and no corrosive gas places 

    Elevation

    ≤2000m

    Class of pollution

    Grade three

    Installation category

    Type Ⅲ

    Dimension

    dimensionygo

    type

    Panel size (mm)

    Shell size (mm)

    Hole size (mm)

    ASJ20

    48*48 (Width*Height)

    43.8*43.8*100 (width*height*depth)

    45*45 (Width*Height)

    Diagram

    diagramw91

    Application

    application116

    Packing&delivery

    packingah7

    Product Selection

    Type

    Function

    Installation

    Appearance

    ASJ10-LD1C

    AC-type residual current measurement; Alarm prompt of current crossing line;

    Rated residual operating current can be measured; Limit non-driving time can be set;

    Two sets of relay output;

    With local and remote “test” and “reset” functions.

    Guide   (DIN  35mm)

     ASJ10-LD1Clrk

    ASJ10-LD1A

    A-type residual current measurement;

    Current percentage light column display;

    Rated residual operating current can be measured; Limit non-driving time can be set;

    Two sets of relay output (settable);

    With local and remote “test” and “reset” functions.

     ASJ10-LD1A4h3

    ASJ10L-LD1A

    A-type residual current measurement;

    Rated residual operating current can be measured;

    Limit non-driving time can be set;

    Two sets of relay output (settable);

    Transformer breakage alarm can be set;

    Pre-alarm value can be set; Return value can be set.

    With on-site display, remote "test", "reset" LCD display, 25 event records.

     ASJ10L-LD1Afmm

    ASJ20-LD1C

    AC-type residual current measurement; Alarm prompt of current crossing line;

    Rated residual operating current can be measured; Limit non-driving time can be set;

    Two sets of relay output;

    With local and remote “test” and “reset” functions.

    Panel (48*48)

     ASJ20-LD1Ct2w

    ASJ20-LD1A

    A-type residual current measurement;

    Current percentage light column display;

    Rated residual operating current can be measured; Limit non-driving time can be set;

    Two sets of relay output (settable);

    With local and remote “test” and “reset” functions.

     ASJ20-LD1Aec2